Tech Papers
Software Simulation of a Double-Sided PCB
Mentor Graphics
Mentor Graphics Technical Library
May 2009
This paper covers the cooling analysis from conceptual design through detailed component analysis of predicting junction temperatures of critical components. Industrial grade components are housed in a card cage and have a temperature rating of 85°C. The software simulations indicate the local air in the cardcage has a temperature of 66 Deg C. Presented in this paper are the following: 1) The system level analysis of the card cage. 2) The use of a Computational Fluid Dynamics tool (Flotherm) which was used to simulate the heat transfer of the critical components using theta j-a (junction-to-ambient thermal resistance) and theta j-c (junction-to-case thermal resistance). 3) The effect that component density and the effect of a double-sided PCB will have on the temperature rating of a component.